Shop Area: Woodshop Tool: Air Compressor Requires in-person training: No |
Procedure Number MT 110-10, Rev. 0 |
Date 3/3/2022 |
General
This guide provides information on the Quincy QT-7.5 air compressor.
Reference
Maintenance
- Clean or replace air filter (part 2023400852) every 6 months.
- Change oil every 6 months. Use SAE 30 (ISO 100) air compressor oil such as Quin-Cip. 2.5 Quarts.
Specifications
END OF THE PROCEDURE